| Moisture
Ranges |
Minimum 0.0%
Maximum up to 90%.
Each dependent on product. |
| Accuracy |
+/- 0.1 of measured value.
Each dependent on product. |
| Repeatability |
+/- 0.1 of measured value.
Each dependent on product. |
| Stability |
One Calibration per year. |
Operating
Temperature |
32 to 122 degrees Fahrenheit;
0 to 50 degrees Centigrade |
Storage
Temperature |
-4 to 158 degrees Fahrenheit;
-20 to 70 degrees Centigrade
NOTE:
In higher
operating temperature environments, we can provide cooling
systems that meet your specific needs. |
Sensor / Sample
Distance |
4 to 12 inches;
10 to 30 centimeters |
| Sampling Size |
Approximately 1 inch or 25 mm in diameter
on sample |
| Sensor
Construction |
Cast aluminum housing designed to meet
requirements of IP65; NEMA 4X |
| Dimensions |
12.1” x 7.1” x 6.4”;
31cm x 18cm x 16cm;
excluding mounting brackets & air
purge tube |
| Weight |
15.5 pounds;
7 Kilograms |
| Outputs |
3 x 4-20 ma isolated analog outputs RS232/485/422
isolated digital outputs (optional)
Ethernet communication
Various LAN’s (optional)
IR communication channel
|
| Power Requirements |
85-250VAC; 50/60 hertz (auto switched)
25 watts power consumption |
Local Area Network
Protocols include |
Ethernet, DeviceNet, Profibus, Modbus,
Canbus, Fieldbus and TCP/IP |